Hobo Jungle

Play nice and have fun... AS OF JULY 12 2025, THIS FORUM IS LOCKED.
User avatar
2railjon
Posts: 15906
Joined: Fri Apr 02, 2004 2:33 pm

Postby 2railjon » Tue Jul 10, 2007 6:30 pm

Thank You, Wayne and Andre!!!!!!!! :D :D :D :D :wink:
Running that red block Charlie.

User avatar
webenda
Posts: 15428
Joined: Sun Jan 09, 2005 4:05 pm
Location: Columbia

Postby webenda » Tue Jul 10, 2007 7:46 pm

AG wrote:Hi Wayne
The capacitor are necessaries for short voltage interruptions.
A.


Andre,

Correcto usted es.

Jon,

Andre is correct. Capacitors will prevent the lamps from flickering when rail contact is lost due to dirty rails. I would try 10 uF, 35 V caps. If the lights still flicker, go larger. maybe 100 uF, 35 V on the first cap.
----Wayne----

Back when I was growing up, if you didn't start someth'n, there wouldn't be noth'n.
--Merle Haggard

User avatar
Daisy
Posts: 1341
Joined: Mon Mar 08, 2004 4:26 pm
Location: B&M

Postby Daisy » Tue Jul 10, 2007 8:36 pm

Andre is Correct!!!!!

TINY!!!!!!! Where areyou?!?!!?!?!?!

User avatar
hev52
Posts: 4741
Joined: Thu Feb 05, 2004 8:34 pm
Location: Hev's Island

Postby hev52 » Tue Jul 10, 2007 10:27 pm

Dirt......................man that's a good idea with the balloons.................... :lol: :lol:

Maybe we could rig something like that and balloon Jon's *** up here to Pennsy.................... :o :o :wink:


Looks like the Rosie The Guard Dog is on duty checkin' out the turtle................ :lol: :lol:




hev 8)
If you want to find history, follow the train man..................Image

User avatar
hev52
Posts: 4741
Joined: Thu Feb 05, 2004 8:34 pm
Location: Hev's Island

Postby hev52 » Tue Jul 10, 2007 10:58 pm

Had to take the Fire Safety Trailer out today and set it up with the with the National Guard today for the kids. Man...................was it hot and humid 94 at 10:00 this morning. Unreal........................ :o :o

Here are a few Pictures................................


Image



Here is what you need Jon...................................



Image




Image




Image




Image




Image





Image




Image




Image




hev 8)
If you want to find history, follow the train man..................Image

User avatar
hev52
Posts: 4741
Joined: Thu Feb 05, 2004 8:34 pm
Location: Hev's Island

Postby hev52 » Tue Jul 10, 2007 11:13 pm

Happy B-day there Mike.

Rosie will git yur cocktail fer ya..............................









Image





hev 8)
If you want to find history, follow the train man..................Image

User avatar
webenda
Posts: 15428
Joined: Sun Jan 09, 2005 4:05 pm
Location: Columbia

RC Time Constant

Postby webenda » Wed Jul 11, 2007 1:08 am

Earlier today I took a wild guess at what value of capacitor would be required for the voltage regulator. Now that I am off work, I can spend some time with the math for RC time constants.

RC TIME CONSTANT

The time required to discharge a capacitor to 37 percent of its initial voltage is known as the Time Constant of the circuit.

Running conventional mode you will be using 10 to 18 Volts or 14.4 to 25 Volts Peak (voltage available to charge capacitor.) 37% of 14.4 VDC is 5.3 VDC. Not quite enough for the voltage regulator but don't forget the capacitor on the output of the regulator will help keep the lamp lit. Thirty seven percent of 25 VDC is 9.25 Volts. More than enough.

One form of the formula used in calculating RC time constants is:
t(in microseconds)=R(in ohms) X C(in microfarads)

The lamp shown in the picture (see the link I gave above) draws .025 amps at 6 Volts so the resistance is R=V/I=6/0.025=240ohms. At 5 volts the resistance is a little less but 240 ohms is close enough for estimating the capacitance required. Plugging 240 ohms into the TC formula for various values of capacitance:

0.1uf: t=RC=240x0.1=2.4 us
1uf: t=RC=240x1=240 us
10uf: t=RC=240x10=2400us=2.4 sec
100uf: t=RC=240x100=24,000us=24 sec

How many microseconds do we need? You cannot see a lamp flashing at 60 Hz (17 us) or 30 Hz (33 us). You can see a 15 Hz (67 us) flicker. So 1 uf should work, giving enough voltage to keep the lamp lit during a 240 us glitch in power. Two lamps... 120 us. Three lamps... 80 us.

Happy birthday Mike.
----Wayne----

Back when I was growing up, if you didn't start someth'n, there wouldn't be noth'n.
--Merle Haggard

zeke-a-nator

Postby zeke-a-nator » Wed Jul 11, 2007 5:34 am

thought id drop in and say hi.

Hev thats a sweet humvee, attracts attention, good way to get the attention of the younger generation

User avatar
2railjon
Posts: 15906
Joined: Fri Apr 02, 2004 2:33 pm

Postby 2railjon » Wed Jul 11, 2007 7:58 am

Hev, If that Humvee is anything like the ones we use- I could'nt afford to keep it on the road!!!! :D

Wayne, I'll be using 3 of these lamps in the tender in parallel on one circuit and 4 of the same in the engine on another circuit for those marker lights. Will I use the same cap as what your recommending for a 6 volt light? :arrow: 1.5V 1.2MM Diameter, 15mA
Also, Will a 1.0 uf work instead of a 0.1 uf?
Running that red block Charlie.

User avatar
AG
Posts: 5017
Joined: Sat May 20, 2006 7:41 pm
Location: Boynton Beach FL.

Postby AG » Wed Jul 11, 2007 8:47 am

highrailjon wrote:Hev, If that Humvee is anything like the ones we use- I could'nt afford to keep it on the road!!!! :D

Wayne, I'll be using 3 of these lamps in the tender in parallel on one circuit and 4 of the same in the engine on another circuit for those marker lights. Will I use the same cap as what your recommending for a 6 volt light? :arrow: 1.5V 1.2MM Diameter, 15mA
Also, Will a 1.0 uf work instead of a 0.1 uf?

You must to use 4 lamps 1.5 x 4= 6 volts if you use less you will increase voltage on the rest and reduce the life of them.
A.
"You can checkout any time you like, but you can't never leave"
www.riverleafmodels.us.

User avatar
2railjon
Posts: 15906
Joined: Fri Apr 02, 2004 2:33 pm

Postby 2railjon » Wed Jul 11, 2007 8:50 am

Andre, how about the 1.0 instead of the 0.1 caps?
Running that red block Charlie.

User avatar
AG
Posts: 5017
Joined: Sat May 20, 2006 7:41 pm
Location: Boynton Beach FL.

Postby AG » Wed Jul 11, 2007 8:56 am

highrailjon wrote:Andre, how about the 1.0 instead of the 0.1 caps?

depend how much room you have too.
you can use 4000 uf if you want, but is huge. 100 uf for your lamp will work ok at low speed over the swtiches.
Andre.
Last edited by AG on Wed Jul 11, 2007 9:22 am, edited 1 time in total.
"You can checkout any time you like, but you can't never leave"
www.riverleafmodels.us.

User avatar
2railjon
Posts: 15906
Joined: Fri Apr 02, 2004 2:33 pm

Postby 2railjon » Wed Jul 11, 2007 9:04 am

How about this one?
1.0µF 35V 20% Dipped Tantalum Capacitor
Model: 272-1434 | Catalog #: 272-1434
Image
Running that red block Charlie.

User avatar
AG
Posts: 5017
Joined: Sat May 20, 2006 7:41 pm
Location: Boynton Beach FL.

Postby AG » Wed Jul 11, 2007 9:28 am

highrailjon wrote:How about this one?
1.0µF 35V 20% Dipped Tantalum Capacitor
Model: 272-1434 | Catalog #: 272-1434
Image

Go to bigger one.
bigger is better (is what she said)
A.
"You can checkout any time you like, but you can't never leave"
www.riverleafmodels.us.

The Dirt
Posts: 3067
Joined: Sun Jun 24, 2007 2:54 pm
Location: Orangeville, Pa.

Postby The Dirt » Wed Jul 11, 2007 10:16 am

Detective Will Rothfuss was in his office studying the light from his one small window falling on his super burrito when the door swung open to reveal a woman whose body said you've had your last burrito for a while, whose face said angels did exist, and whose eyes said she could make you dig your own grave and lick the shovel clean.


Return to “The Club Car Lounge”

Who is online

Users browsing this forum: No registered users and 59 guests